Product Description REAGEN™Zilpaterol Strip Test is a qualitative and rapid lateral flow assay designed to detect  zilpaterol residues in urine, feed and milk sample.  Th

  • Brand:REAGEN
  • Model:RNS92015

Product Description

 

REAGENZilpaterol Strip Test is a qualitative and rapid lateral flow assay designed to detect  zilpaterol residues in urine, feed and milk sample.

 

 

The unique features of the kit are:

 

 

l Rapid strip test method  12 minutes

lNovel binding protein that requires no heating step

l High sensitivity3-5ppb

lHigh reproducibility

 

 

Mechanism of Reaction


REAGEN The assay uses a competitive colloidal gold based format. The extration sample (100 μL) is added to a clear plastic reaction vessel, and used to resuspend the lyophilized reagents to a uniform pink color in the bottom of the microtiter wells. The sample is incubated briefly (4 min) to allowed to flow up the strip for 8 minutes by capillary action. The anti-zilpaterol antibodies on the gold particles engage with any Zilpaterol present in the sample. Any gold particles that are not complexed with zilpaterol present in the sample will bind to the zilpaterol imprinted at the Test line (T-line), forming a signal (red line) at that position. If the Anti-zilpaterol antibodies on the gold particles have engaged with zilpaterol present in the sample, the gold particle will flow past the T-line and reach the Control line (C-line). For visual interpretation of the test results, T-line signal intensity that is stronger or equal to the signal at the C-line indicates a negative result. Signal at the T-line which is less intense than the C-line indicates the presence of trace levels of zilpaterol in the sample (3-5 ppb*dilution factor)

 

Kit Contents, Storage and Shelf Life

 

The REAGEN Zilpaterol Strip Test has the capacity for 96(RNS92015).The shelf life is 12 months when the kit is properly stored.

 

Kit Contents

Amount

Storage

Reaction Wells

12T x8  (96 total)

RT(25˚C+/- 2.5)

(Dry,dark and well sealed )

Test Strips

48T x2  (96 total)

Microplate

1

RT(25˚C+/- 2.5)

Extration Buffer

1 vial(28mL)

Manual

1

 

A 96-wells plastic frame is also provided in each kit to anchor the reaction wells in place during testing, and can be re-used as required.

Sensitivity (Detection Limit)

 

Milk

3-5ppb

Test line obvious weaker than control line

Bovine and swine urine

3-5ppb

Test line obvious weaker than control line

Bovine and swine feed

18-30ppb

Test line obvious weaker than control line

 

 

 

 

 

 

 

Required Materials Not Provided With the Kit

 

Timer

Additional positive and negative controls

Polypropylene tubes

Centrifuge (or filter paper)

Distilled water

Scissors to cut strip caps

Disposable fixed volume pipettor (200 µL and 1000 µL)

2Mol/L NaOH

 

 

Warnings and Precautions

 

Do not use the kit past the expiration date.

Do not re-use pipette tips or polypropylene tubes.

Be sure unused wells remain tightly sealed with the plug caps.

Incubations of assay should be timed as precisely as possible

Always store test strips in provided vials to maintain stability.

Positive samples should always be re-tested alongside a positive and negative control.