Full Spectrum Micropate Reader

RNE-90001 Full Spectrum Micropate ReaderIntroduction1)RNE90001 is a microprocessor –controlled, general purpose photometer system designed to read and calculate the result of assays, including co

  • Brand:REAGEN
  • Model:RNE90003
  • Specifications:1platform
  • Price:5948.00USD

RNE90003 Full Spectrum Micropate Reader

image34.jpg

Introduction

1)RNE90003 is a microprocessor –controlled, general purpose photometer system designed to read and calculate the result of assays, including contagion, tumorous mark, hemopathy, dyshormonism, which are read in microtiter plate.

2)Touch panel let your operation easily.


3)Multiple calculations:


lAbsorbance mode (ABS)


lCut-Off mode


lSingle standard mode


lPoint to point mode


l% Absorbance Multi-Point Mode


lLinear regression mode


lExponent regression mode


lLogarithm regression mode


lPower regression mode


4) isualization mark plate,you can set blank, 


control, sample ,standard in any place,and


run mostly 12 different tests in one 96 micr


plate.


5) Test time <5s/plate,and mix plate before


test

6)Item parameter settings: parameters of 120 detection items can be set, saved and queried for future detection;

7)Detection calibration: detection calibration is enabled, calibration parameters of 120 last items can be saved, calibration parameters can be transferred while do the same item detection;                                         

Parameters of instrument

Weight:

8.1kg

Overall dimensions:

430mm(L)×335mm(L)×175mm(L)

Power:

a.c.110V~220V50-60Hz

Fuses:

T2AL250V

Work Environment:

temperature 10-30Humidity ≤70%

Store Environment:

-20-55Humidity ≤93%

Standard Wavelength:

405450492630nmTen optical fibers can be configured within 400 to 800 at a

time;

Instrument sensitivity:

no less than 0.01L/mg.

Instrument channel difference:

less than 0.01A.

Range of operating wavelength:

400-800nm;

Detection range:

0.000-4.000A;

Resolution ratio:

0.001A;

Plate reading velocity:

5s of single waveform, 10s of dual wavelength;

Warm up time:

10 minute

Interface:

RS-232C serial interface, USB interface

Display:

5.7″LCD display(320×240 discernibility,256 gray scale)

Input:

Touch panel and pen,

Accuracy

±0.01(0.000-2.000nm)

Linear error

±1.0%(0.000-2.000nm)

Accurate wavelength

±3.0nm